Eddy Current Damping Suppression of Long Primary Linear Synchronous Motor
ID:30 View Protection:PUBLIC Updated Time:2021-06-22 09:12:22 Hits:1472 Poster Presentation

Start Time:2021-07-02 16:02(Asia/Shanghai)

Duration:1min

Session:SP Poster Session » P3Poster Session 5 & 6

Abstract
Eddy current is generated by time-varying current in the armature and the back EMF causing by moving magnets in the cooling plate. It produces a damping force influencing the motor’s dynamic characteristic. In this paper, a new method is introduced to suppress eddy current by offsetting back EMF. The correction of the method and effect of eddy current suppression is proved by simulation: 95% reduction in the damping force significantly help with reducing the thrust fluctuation. The new cooling plate is designed into a unit module, and it can combine with others to make cooling plates of different lengths.
Keywords
Eddy current, Long primary, cooling plate