Analysis of Crystalline Silica Aerosol Using Portable Raman Spectrometry: Feasibility of Near Real-Time Measurement
ID:135 View Protection:ATTENDEE Updated Time:2022-05-12 21:52:59 Hits:1627 Invited speech

Start Time:2022-05-27 15:20(Asia/Shanghai)

Duration:20min

Session:S6 Occupational Safety and Health » S6-3Occupational Safety and Health-3

No files

Abstract
A Raman spectroscopy based method has been developed for measurement of trace airborne concentrations of respirable crystalline silica (RCS). Three aerosol microconcentration techniques were investigated for effective coupling of collected particulate samples with micro-Raman spectroscopy: (i) direct analysis on a particulate filter after focused aerosol collection using a converging nozzle; (ii) analysis of dried particulate deposit on a filter obtained directly from the aerosol phase using the Spotsampler device; and (iii) analysis of a dried spot (similar to 1-3 mm diameter) obtained by redepositing the particulate sample, after low temperature plasma ashing of the filter sample. The deposition characteristics (i.e., spot diameter, shape, and deposit uniformity) of each technique were investigated. Calibration curves were constructed and detection limits were estimated for a-quartz using the A(1) Raman Si-O-Si stretching bending phonon mode at 465. The measurement sensitivity could be substantially improved by increasing the signal integration time and by reducing the particle deposition area. Detection limits in the range of 8-55 ng could be achieved by microconcentrating the aerosol sample over a spot measuring 400-1000 mu m in diameter. These detection limits were two to three orders of magnitude lower compared to those attainable using current standardized X-ray diffraction and infrared spectroscopy methods. The low detection limits suggest that near real-time measurements of RCS could be achieved with limits of quantification ranging from 2 to 18.5 mu g/m3 (at 10 min collection time and 1.2 L/min), depending on microconcentration technique used. The method was successfully extended to the measurement of alpha-quartz air concentration in representative workplace aerosol samples. This study demonstrates the potential of portable micro-Raman spectroscopy for near-real time measurement of trace RCS in air.
Keywords
Raman spectroscopy,respirable crystalline silica,dust monitoring,real-time measurements
Speaker
Lina ZHENG
China University of Mining and Technology

Submission Author
丽娜 郑 中国矿业大学
温婷 冯 中国矿业大学
臻 韩 中国矿业大学
Submit Comment
Verify Code Change Another
All Comments
Important Date
  • Conference Date

    May 26

    2022

    to

    May 27

    2022

  • May 03 2022

    Draft paper submission deadline

  • May 26 2022

    Contribution Submission Deadline

  • May 28 2022

    Registration deadline

Sponsored By
China University of Mining and Technology
Contact Information